Remarks
The vertical position of the cursor is defined by the pixel coordinate of the screen. The range of the pixel
coordinate on the screen vertically is from 0 to 399 (from top to bottom).
Return Format
The query returns an integer between 0 and 399.
:CURSor:MANual:IXDelta?
Syntax
:CURSor:MANual:IXDelta?
Description
Queries the reciprocal (1/
△
X) of the difference between X values at Cursor A (X cursor) and Cursor B (X
cursor) in the manual mode of cursor measurement. The unit is determined by the currently selected
horizontal unit.
Remarks
For the horizontal position of Cursor A (X cursor), refer to the :CURSor:MANual:CAX command.
For the horizontal position of Cursor B (X cursor), refer to the :CURSor:MANual:CBX command.
Return Format
The query returns the reciprocal (1/
△
X) of the difference between X values in scientific notation. When
△
X
is 0 s, the query returns 9.9e37.
:CURSor:MANual:SOURce
Syntax
:CURSor:MANual:SOURce <source>
:CURSor:MANual:SOURce?
Description
Sets or queries the source channel of the manual mode of cursor measurement.
Parameter
Name
Type
Range
Default
<source>
Discrete
{CHANnel1|CHANnel2|CHANnel3|CHANnel4|MATH|NONE} CHANnel1
Remarks
Only the currently enabled channel can be selected as the source channel.
When <source> is set to "NONE", neither cursors nor measurement results will be displayed.
Return Format
The query returns CHAN1, CHAN2, CHAN3, CHAN4, MATH, or NONE.
:CURSor:MANual:TUNit
Syntax
:CURSor:MANual:TUNit <unit>
:CURSor:MANual:TUNit?
Description
Sets or queries the horizontal unit in the manual mode of cursor measurement.