RIGOL
DS4000E Programming Guide
2-157
:MEASure:VAVG:SAVerage
:MEASure:VAVG:SCURrent
:MEASure:VAVG:SDEViation
:MEASure:VAVG:SMAXimum
:MEASure:VAVG:SMINimum
Syntax 1
:MEASure:VAVG:SAVerage [<chan>]
:MEASure:VAVG:SCURrent [<chan>]
:MEASure:VAVG:SDEViation [<chan>]
:MEASure:VAVG:SMAXimum [<chan>]
:MEASure:VAVG:SMINimum [<chan>]
Description 1
Measures the amplitude average value of the specified source channel and enables the statistic function of
the measurement results.
Syntax 2
:MEASure:VAVG:SAVerage? [<chan>]
:MEASure:VAVG:SCURrent? [<chan>]
:MEASure:VAVG:SDEViation? [<chan>]
:MEASure:VAVG:SMAXimum? [<chan>]
:MEASure:VAVG:SMINimum? [<chan>]
Description 2
Queries the average value, current value, standard deviation, maximum value, or minimum value of the
amplitude average value measurement results when the amplitude average value measurement function of
the specified source channel and the statistic function of the measurement results are enabled. The unit is
related to the current amplitude unit of the specified source channel.
Parameter
Name
Type
Range
Default
<chan>
Discrete
{CHANnel1|CHANnel2|CHANnel3|CHANnel4|MATH}
--
Remarks
Before making measurements, turn on the channels to be measured.
When the math operation type is FFT (refer to the :CALCulate:MODE command), <chan> cannot be
set to "MATH".
When [<chan>] is omitted, the command, by default, applies to the currently set measurement source
(refer to the :MEASure:SOURce command).
Return Format
The query returns the average value, current value, standard deviation, maximum value, or minimum value
in scientific notation. When the measurement results are invalid, the query returns 9.9e37.