:CALCulate:DIVision:VOFFset
Syntax
:CALCulate:DIVision:VOFFset <offs>
:CALCulate:DIVision:VOFFset?
Description
Sets or queries the vertical position of the division operation waveform. The unit is related to the current
amplitude unit of the source channel.
Parameter
Name
Type
Range
Default
<offs>
Real
(-40 x vertical scale of the division operation waveform) to (40 x
vertical scale of the division operation waveform)
0
Return Format
The query returns the vertical position in scientific notation.
:CALCulate:DIVision:VSCale
Syntax
:CALCulate:DIVision:VSCale <scale>
:CALCulate:DIVision:VSCale?
Description
Sets or queries the vertical scale of the division operation waveform. The unit is related to the current
amplitude unit of the source channel.
Parameter
Name
Type
Range
Default
<scale>
Real
Refer to Remarks
2 U/div
Remarks
The default range of <scale> is from 20 nU/div to 100 MU/div. Its actual range is related to the vertical
scale of the source channel (refer to the :CHANnel<n>:SCALe command), at 1-2-5 step.
Note: After the vertical scale of the source channel is modified, the range of <scale> will not be changed
until the division operation is re-enabled.
Return Format
The query returns the vertical scale in scientific notation.