RIGOL
DS4000E Programming Guide
2-97
:FUNCtion:WANalyze:SETup:SSTart
Syntax
:FUNCtion:WANalyze:SETup:SSTart <point>
:FUNCtion:WANalyze:SETup:SSTart?
Description
Sets or queries the screen start point (in pixel) in waveform analysis.
Parameter
Name
Type
Range
Default
<point>
Integer
5 to 685
5
Remarks
The range of the pixel coordinate on the screen horizontally is from 0 to 699 (from left to right).
The actual range of the screen start point is from 5 to "currently set screen end point - 10".
Return Format
The query returns an integer between 5 and 685.
:FUNCtion:WANalyze:SETup:THReshold
Syntax
:FUNCtion:WANalyze:SETup:THReshold <thre>
:FUNCtion:WANalyze:SETup:THReshold?
Description
Sets or queries the error frame threshold in waveform analysis.
Parameter
Name
Type
Range
Default
<thre>
Integer
1 to 99
10
Remarks
The error frame threshold is used to judge whether the data frame is an error frame. In different waveform
analysis modes (refer to the :FUNCtion:WANalyze:MODE command), the methods for judging the error
frame are different.
Return Format
The query returns an integer between 1 and 99.
:FUNCtion:WANalyze:SETup:XMASk
Syntax
:FUNCtion:WANalyze:SETup:XMASk <mask>
:FUNCtion:WANalyze:SETup:XMASk?
Description
Sets or queries the horizontal tolerance range of the pass/fail test mask when the waveform analysis mode
is "Pass/Fail". The default unit is div (in the horizontal direction).
Parameter
Name
Type
Range
Default
<mask>
Real
0.02 to 4 (with a step of 0.02)
0.24