![Rigol DS4000E Series Programming Manual Download Page 246](http://html1.mh-extra.com/html/rigol/ds4000e-series/ds4000e-series_programming-manual_1460996246.webp)
RIGOL
2-234
DS4000E Programming Guide
:TRIGger:VIDeo
Command List:
:TRIGger:VIDeo:LEVel
Syntax
:TRIGger:VIDeo:LEVel <level>
:TRIGger:VIDeo:LEVel?
Description
Sets or queries the trigger level of Video trigger. The unit is the same as the current amplitude unit of the
source channel.
Parameter
Name
Type
Range
Default
<level> Real
The range of <level> is from (-6 x VerticalScale - Offset) to (6 x
VerticalScale - Offset) (relative to the vertical center of the screen).
Wherein, VerticalScale is the vertical scale of the source channel,
refer to the :CHANnel<n>:SCALe command; Offset is the vertical
position of the source channel, refer to the :CHANnel<n>:OFFSet
command.
0
Return Format
The query returns the trigger level in scientific notation.
:TRIGger:VIDeo:LINE
Syntax
:TRIGger:VIDeo:LINE <line>
:TRIGger:VIDeo:LINE?
Description
Sets or queries the line number of Video trigger when the sync trigger mode is "LINE" (refer to
the :TRIGger:VIDeo:MODE command).
Parameter
Name
Type
Range
Default
<line>
Integer
Related to the video standard currently selected (refer to
the :TRIGger:VIDeo:STANdard command):
NTSC: 1 to 525
PALSecam: 1 to 625
480P: 1 to 525
576P: 1 to 625
720P: 1 to 750
1080P: 1 to 1125
1080I: 1 to 1125
1