Installation (picture

���

)

These compressors may not be operated without the standard pressure regulating and limiting valves fitted so that the maximum
pressure is not exceeded (see data plate).

For operating and installation follow any relevant national standards that are in operation.
1. Pressure connection at (B).

Long and/or small bore pipework should be avoided as this tends to reduce the capacity of the compressor.

2. The lubricating oil (recommended brands see under servicing) can be put into the pump at the oil filler port (H) of the oil tank, until the oil level

shows at the upper mark of the oil sight glass (l). After filling make sure the oil filler port is closed.

3. The electrical data can be found on the data plate (N) or the motor data plate. The motors correspond to DIN/VDE 0530 and have IP 54

protection and insulation class B or F. The connection diagram can be found in the terminal box on the motor (unless a special plug connection
is fitted). Check the electrical data of the motor for compatibility with your available supply (voltage, frequency, permissible current etc.).

4. Connect the motor via a motor starter. It is advisable to use thermal overload motor starters to protect the motor and wiring.  All cabling  used

on starters should be secured with good quality cable clamps.
We recommend that motor starters should be used that are fitted with a time delayed trip resulting from running beyond the amperage setting.
When the unit is started cold overamperage may occur for a short time.

The electrical installation may only be made by a qualified electrician under the observance of EN 60204. The main switch must
be provided by the operator.

Initial Operation (picture

���

)

1. Initially switch the pump on and off for a few seconds to check the direction of rotation against the direction arrow (O).
2. Connect the pressure pipe at (B).
3. The required pressure ranges can be adjusted by turning the pressure regulating valve (D) according to the symbols on the top of the regulating

valve.

Potential risks for operating personnel
1. Noise Emission: The worst noise levels considering direction and intensity measured according to DIN 45635 part 3 (as per 3. GSGV) are shown

in the table at the back. When working permanently in the vicinity of an operating compressor we recommend wearing ear protection to avoid
any damage to hearing.

2. Oil mist in the Exhaust Stream: Even with the  oil sieves the exhausted air could still contain extremely low amounts of oil mist which can

occasionally be detected by smell. Permanent breathing of these mists may result in health problems, therefore it is extremely important to make
sure that the installation area is well ventilated.

Maintenance and Servicing

When maintaining these units and having such situations where personnel could be hurt by  moving parts or by live electrical parts
the compressor must be isolated by totally disconnecting the electrical supply. It is imperative that the unit cannot be re-started

during the maintenance operation.
Do not maintain a compressor that is at its normal operating temperature as there is a danger from hot parts or hot lubricant.

1. Lubrication (pictures 

���

)

Check the oil level regularly depending upon the operating hours. First oil change after 200 operating hours (see oil drain plug (K)). Further changes
every 1000 operating hours. The oil change times should be shortened if the application is dusty.
Only oils corresponding to DIN 51 506 group VB / VBL or a synthetic oil (obtainable from Rietschle) should be used. The viscosity must corre-
spond to ISO-VG 320 according to DIN 51 519.
The recommended Rietschle Oil types are: MULTI-LUBE 320 (mineral oil); SUPER-LUBE 320 (synthetic oil) (see oil type plate (M)).
When the oil is under a high thermal load, e.g. ambient or suction temperatures over 30°C,  unfavourable cooling or operating with increased
speed etc., the oil change time can be extended by using the recommended synthetic oil.

Old and used oil must be disposed of corresponding with the relevant health, safety and environmental laws.
If the oil brand is changed, the old oil must be drained completely from  the oil tank.

2. Oil separation (pictures 

���

 and 

���

)

The oil separation of the compressed air is carried out by an oil separation system that needs very little maintenance. The first oil separation takes
place by blowing up the air onto an oil sieve (t

1

). The fine oil separation however, is done by blowing air onto oil sieves (t

2

) which are accessible

on the service side of the unit. We recommend that the sieves should be rinsed and cleaned in benzine or a similar fluid at least once a year and
for this purpose covers (T

1

) and (T

2

) are to be removed.

Summary of Contents for DCLF 100 D

Page 1: ...ar Dauerbetrieb ist zul ssig Die abgesaugte Luft darf kein Wasserdampf Wasser und andere Fl ssigkeiten enthalten Aggressive oder brennbare Gase oder D mpfe d rfen nicht abgesaugt werden Die Umgebungst...

Page 2: ...Wir empfehlen bei andauerndem Aufenthalt in der Umgebung des laufenden Verdichters das Benutzen pers nlicher Geh rschutzmittel um eine Dauersch digung des Geh rs zu vermeiden 2 laerosole in der Abluf...

Page 3: ...ld Je nach Arbeitsbedingungen unterliegen die Kupplungs gummis k einem Verschlei und sollten von Zeit zu Zeit berpr ft werden Verschlissene Kupplungsgummis ma chen sich durch ein schlagendes Ger usch...

Page 4: ...t zu rasch aus Abhilfe Verwendung eines Motorschutzschalters mit berlastabh ngiger Abschaltverz gerung die den kurzzeitigen berstrom beim Start ber cksichtigt Ausf hrung mit Kurzschlu und berlastausl...

Page 5: ...oduce pressure up to the maximum limits which are shown at the data plate N They may be operated continuously Amounts of water vapour water other liquids aggressive gases or vapours may not be handled...

Page 6: ...ng permanently in the vicinity of an operating compressor we recommend wearing ear protection to avoid any damage to hearing 2 Oil mist in the Exhaust Stream Even with the oil sieves the exhausted air...

Page 7: ...Coupling picture The coupling rubbers k are wearing parts and should be checked regularly When the coupling rubbers are worn this can be detected by a knocking sound when the compressor pump is start...

Page 8: ...ting on the motor starter 1 4 Motor starter trips too fast Solution Use a motor starter with a time delay trip version as per IEC 947 4 1 5 The compressor is too cold 1 6 The regulating valve is dirty...

Page 9: ...les bar indiqu es sur la plaque signal tique N Un fonctionnement en continu ces valeurs est possible L air aspir ne doit contenir ni vapeur d eau ni de l eau ou autres liquides Des gaz agressifs ou in...

Page 10: ...ement En d pit du d shuilage tr s pouss obtenu par le filtre s parateur d huile des a rosols r siduels en quantit minime sont refoul s et d tectables leur odeur La respiration continue de ces a rosols...

Page 11: ...oucs d accou plement k sont soumis une usure et doivent tre v rifi s de temps autre Des caoutchoucs us s sont reconnaissables un bruit anormal de cognement lors du d marrage de l appareil Des caoutcho...

Page 12: ...un disjoncteur coupure temporis e qui tiendra compte d une ventuelle surintensit au d marrage ex cution VDE 0660 Partie 2 ou IEC 947 4 1 5 Compresseur trop froide 1 6 Le valve de r glage est encrass e...

Page 13: ...a N E consentito il funzionamento continuato L aria aspirata pu contenere vapore acqueo ma non acqua e altri liquidi inoltre non devono essere aspirati gas aggressivi o combustibili La temperatura amb...

Page 14: ...ata in sala macchine di utilizzare protezioni individuali per le orecchie per evitare danni irreversibili all udito 2 Aereosol allo scarico Nonostante la separazione dell olio attraverso gli elementi...

Page 15: ...unto Fig In base alle condizioni di funzionamento i giunti in gomma k sono soggetti ad usura e devono quindi essere controllati periodicamente I giunti in gomma usurati sono riconoscibili dal forte ru...

Page 16: ...l salvamotore troppo rapido Rimedio utilizzo di un salvamotore con sganciamento ritardato che tenga conto della sovracorrente allo spunto Esecuzione con interruttore di cortocircuito e di sovraccarico...

Page 17: ...ltet N angivne maksimale tryk i bar Kontinuerlig drift er tilladt Den evakuerede luft m indeholde vanddamp men ikke vand og andre v sker Pumpen er ikke konstrueret til befordring af aggressive gasser...

Page 18: ...erosol i afgangsluft Selv om vakuumpumperne har et meget effektivt oliesepareringssystem kan det ikke undg s at der er olielugt og olieaerosol i afgangsluften Konstant ind nding af denne luft kan v re...

Page 19: ...indefra bankes ud i h nden eller udskiftes Indbygning sker i omvendt r kkef lge 4 Kobling billede Koblingsgummi k slides og ldes og skal derfor regel m ssigt udskiftes N r koblingsgummi er defekt h re...

Page 20: ...urtigt ud Afhj lpning anvend motorv rn med tidsforsinket udkobling efter VDE 0660 del 2 hhv IEC 947 4 1 5 Tryk vakuumpumpe er for kold 1 6 Tryk og vakuumreguleringsventiler er tilstoppede s ledes at d...

Page 21: ...aangezogen lucht mag waterdamp bevatten maar geen water of andere vloeistoffen Agressieve of brandbare gassen mogen niet verpompt worden De omgevingstemperatuur en de temperatuur van de aangezogen lu...

Page 22: ...ponthoud in de nabijheid van de draaiende compressor gehoorbeschermende middelen te gebruiken om een blijvende beschadiging van het gehoor te vermijden 2 Oliedampen in de uitblaaslucht Ondanks de best...

Page 23: ...et gebruik ondergaan de koppelings rubbers k een zekere slijtage en dienen van tijd tot tijd gecontroleerd te worden Versleten koppelingsrubbers zijn te constateren door een sterk ratelend geluid tijd...

Page 24: ...chakelaar is niet juist afgesteld 1 4 Motorbeveiligingsschakelaar valt te snel uit Oplossing Gebruik van een motorbeveiligingsschakelaar met vertraagde overbelasting uitschakeling die de kortstondige...

Page 25: ...yores Las unidades DCLF D generan una presi n hasta los l mites m ximos que figuran en la placa de datos N Son aptos para el funcionamiento continuo No deben aspirarse vapor de agua agua otros l quido...

Page 26: ...Aceite atomizado en la salida A pesar del alto rendimiento del separador de vapor de aceite el aire expulsado puede contener cantidades extremadamente reducidas de aceite atomizado que puede detectars...

Page 27: ...a desgaste y deben comprobarse de forma regular El desgaste de los casqui llos puede detectarse por el golpeteo al poner el compre sor en marcha Los casquillos defectuosos pueden causar se rios da os...

Page 28: ...de prisa Utilizar un retardo versi n IEC 947 4 1 5 El compresor est demasiado fr a 1 6 Presi n excesiva causada por suciedad en la v lvula reguladora 2 Capacidad aspirante insuficiente 2 1 Filtros o m...

Page 29: ...f r inte inneh lla vatten nga vatten eller andra v tskor Pumpen r ej konstruerad att transportera aggressiva eller explosiva gaser och ngor Omgivningstemperaturen och temperaturen p den insugande luft...

Page 30: ...ad med ett h geffektivt oljeavskiljningssystem kan man inte undg att sm m ngder olja f ljer med tryckluften Konstant inandning av denna luft kan vara h lsov dligt och en god ventilation av den lokal d...

Page 31: ...bytas Montering sker i omv nd ordning 4 Koppling bild Allt efter arbetsbelastningen blir kopplingsgummin k utsatta f r slitage och skall d rf r regelbundet kontrolle ras N r kopplingsgummin r defekta...

Page 32: ...kydd r ej r tt inst llt 1 4 Motorskydd l ser f r snabbt tg rd Anv nd motorskydd med f rdr jd funktion 1 5 Kompressorn r f r kall 1 6 Tryckreglerventilen r igensatt och till tet tryck verskrides 2 Kapa...

Reviews: