TECHNICAL ASSISTANCE SERVICE
53
Problem in DHW safety valve
(installed by heating engineer)
- Check valve setting and effi-
ciency
DHW circuit pressure too high
- Check DHW circuit pressure
Problem in DHW expansion vessel
(installed by heating engineer)
- Check efficiency of DHW
expansion vessel
The DHW safety valve
(installed by heating engineer)
opens frequently
Supply pressure too high
- Fit a pressure reducer
Flow rate too high
- Fit a flow reducer
- Check and clean
Lime scale and/or sludge
in storage cylinder
- Check functioning of DHW circuit
pump
- Check settings of control thermo-
stats
- Check positions of sensors
- Check boiler operating
temperature
Insufficient domestic hot water
Pump seized
Bad electrical connection
- Check pump and connections
No heat request temperature
controller
- Check temperature controller,
sensors and connections
The central heating or DHW
pump is not working
- Check CH circuit pressure
- Check pressure reducer
- Check efficiency of safety valve
Incorrect central heating circuit
pressure
Problem in CH expansion vessel
(installed by heating engineer)
Central heating safety valves
open frequently
- Check efficiency of CH expan-
sion vessel
CAuSE
SOluTION
FAulT