1 - Photoresistor
2 - Flange with seal
3 - Blast tube
4 - Oil pump pressure adjuster screw
5 - Pressure gauge fitting
6 - Oil pump
OIl BuRNER
LAYOUT
REMOVING THE BURNER
Proceed as follows to remove the burner:
- Close the fuel shut-off cocks.
- Disconnect the connector (1).
- Unscrew the fixing nut (2) and remove the burner.
Reverse the above steps to reassemble.
b
If the burner needs to be taken completely out of
the boiler, disconnect the hoses (3) first. Use a suit-
able rag to soak up the fuel that inevitably comes
out.
3
1
2
7 - Motor
8 - Reset button with lockout indicator
9 - Burner control box