INSTALLER
23
WATER CONNECTIONS
Sc
Sc
417
630
48
48
170
170
1028
95
230
230
1241
300
300
MI
MI
RI
UAC
EAF
RC
RI
r
INSIEME CONDENS
boilers are designed and made for installation in combined central heating and domestic hot
water production systems. The following table lists the specifications of the water fittings.
b
Install the non-return valve supplied with the boiler in
the central heating flow pipe.
b
The safety valve must be connected to a suitable
collection and drain system. The manufacturer
declines all responsibility for damage caused by
water escaping from the safety valve.
b
Circuits filled with anti-freeze must be fitted with
water disconnectors.
b
Low temperature (under-floor) heating systems must
be fed through a circuit fitted with a mixer valve.
b
The choice of system components and the method
of their installation are left up to the heating engi-
neer installing the system. Installers must use their
expertise to ensure proper installation and function-
ing in compliance with all applicable legislation.
Description
INSIEME CONDENS
26 B
35 B
26 BK
35 BK
MI -
CH flow
1" M
1" M
1" M
1" M
Ø
RI -
CH return
1" M
1" M
1" M
1" M
Ø
UAC -
Domestic hot water outlet
-
-
3/4" F
3/4" F
Ø
EAF -
Domestic cold water inlet
-
-
3/4" F
3/4" F
Ø
RC -
DHW recirculation
-
-
3/4" F
3/4" F
Ø
Sc -
Condensate drain / Safety valve
-
INSIEME CONDENS 26 BK - 35 BK