S-SERIES PRIVATE USE SERVICE MANUAL
MAINTENANCE
SEPTEMBER 2020
3- 17
32DSW02.F
FIGURE 3-40
5. Refer to
Figure 3-41.
Disconnect hydraulic hoses from pump only.
FIGURE 3-41
6. Refer to
Figure 3-42.
Disconnect electrical connections to pump.
Note:
Mark and/or identify wires to ensure proper reconnection.
FIGURE 3-42
7. Refer to
Figure 3-42.
Remove two mounting bolts that mount pump to bracket. Retain for installation.
8. Lift pump out to be replaced with (PM312210112) pump assembly.
9. Re-assembly in reverse order.
10. Check fluid level and check for leaks.
Note:
Platform pressure switch check and adjustment must be performed with 50lb. test procedure. Correct
adjustment of this pressure switch is required to prevent platform from folding into vehicle when there is a
load of 50lbs., or more, on platform. Refer to Chapter 2, Section C.5 for Platform Pressure Switch Check.
Note:
Maximum hydraulic system pressure is factory set at 1100psi.
MOUNTING