S-SERIES PRIVATE USE SERVICE MANUAL
INSTALLATION
SEPTEMBER 2020
2 - 4
32DSW02.F
B. ELECTRICAL INSTALLATION
CAUTION!
•
Do not route a wire if it is connected to the battery.
•
Route wires clear of moving parts, brake lines, and the exhaust system. Secure wires to the vehicle.
•
When routing an electrical wire through vehicle floor or walls, use a grommet to protect wire insulation from
chafing.
•
Check underside of vehicle before drilling to avoid damage to fuel lines, vent lines, brake lines, or wiring.
FIGURE 2-4: ELECTRICAL INSTALLATION DIAGRAM
SIDE PUMP
SOLENOID
#4 RING
SOLENOID
TERMINAL
TOP PUMP
MAIN
BREAKER
4 AWG POWER CABLE:
SOLENOID
SHORT CABLE, NOT TO EXCEED 12",
CONNECTED BETWEEN BATTERY (OR
MAIN POWER SOURCE) AND MAIN
CIRCUIT BREAKER
LONG CABLE CONNECTED BETWEEN
MAIN CIRCUIT BREAKER AND POSITIVE
TERMINAL OF SOLENOID
12VDC BATTERY
TOP PUMP
90 AMP
4 AWG POWER CABLE: