T
echnical
B
ulletin
PAGE: 1/1
Model:
Model TH-C1
Date:
5-Oct-05
No.:
RB156010
Subject:
Firmware History - Web System
Prepared by: H.K.
From:
1st Tech. Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other (Firmware History)
This is to inform you of the Web System firmware history.
Part No.
Program name
B6766530
A
B6766530A.fwu
V1.02.
-
October production ‘05
-
B6766530.fwu
V1.00.
-
February production ‘05
Symptom Corrected
Version
Changed :
The following settings have been added to WIM [Configuration->Device
Settings->System]:
1. Display IP Address on the Display Panel - Displays the device's IP
address on the panel.
2. "Permit ROM Update" - Enable/Disable firmware updates.
3. "Print Priority" function
These settings can only be seen if all 3 of NCS firmware Ver 4.17 or
later, Controller firmware Ver 1.08 or later and Websys firmware Ver
1.02 or later have been applied to the device.
The device now supports the ROM update function via WIM.
[Configuration->ROM Update]
Web Image Monitor is available in Korean.
Some menu items in WIM are incorrectly displayed.
1. SSL settings in German.
(Wrong) [Verschlüsselung/ Text löschen] [Chiffretext/ Text löschen]
(Correct) [Verschlüsselung/ Klartext] [Chiffretext/ Klartext]
2. Administrator Authentication Management in Czech
(Wrong) Správa autorizace uživatele
(Correct) Správa autorizace administrátora
Fixed: LDAP Authentication does not work if configured using the
'LDAP Server 3, 4 or 5' settings from WIM. These settings work correctly
if set from the operation panel.
V1.02
First release
V1.00