SYMPTOM
The BICU board is defective, or the controller board is defective and SC838 occurs
(Verification Error).
CAUSE
A short circuit occurs with the +5VF or +5VE line in the harness between the IO board and
BICU board (P/N B1545408).
z
+5VE short-circuit: The controller board may be defective and SC838 occurs
z
+5VF short-circuit: The BICU board may be defective
Note:
The short circuit can be caused at the factory or in the field (see
Solution
).
Damaged harness
between IO board and
BICU board