T
echnical
B
ulletin
PAGE: 1/2
Reissued: 29-Jun-07
Model:
Model TH-C1
Date:
5-Oct-05
No.:
RB156010b
RTB Reissue
The items in bold italics have been added.
Subject:
Firmware History - Web System
Prepared by: H.K.
From:
1st Tech. Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other (Firmware History)
This is to inform you of the Web System firmware history.
Part No.
Program name
B6766530
B
B6766530B.fwu
V1.03.
July production ‘07
A
B6766530A.fwu
V1.02.
-
October production ‘05
-
B6766530.fwu
V1.00.
-
February production ‘05
Symptom Corrected
Version
Symptom corrected:
1. Errors in the way the French, Portuguese, and Danish for "Used
Toner Bottle" are worded in Web Image Monitor.
2. Attempting to configure an IPP Authentication password of 8 two-
byte numeric digits, will cause the device's web service to stall.
3. "Job Order" can be selected for the Print Priority setting even though
it is not supported by the device (GFPR#RC06040005).
WIM > Device Settings > System > Print Priority > Job Order
4. Accessing the document server in WIM via a single sign-on server
might result in "404 Not Found". This only happens if the url used to
access WIM contains a "Host Name" and "Domain Name" (The
"domain name" setting in the MFP is not blank.). It does not happen if
the url contains an IP address.
Note: To fix this issue, all of the following firmware must be applied:
- System (Controller) firmware ver 1.14.1 or later
- Websys firmware ver 1.03 or later
- WebDocBox firmware ver 1.02 or later
- Netfile firmware ver 2.00 or later
- Printer firmware ver 1.06 or later
V1.03