Symptom Corrected
Version
The Document Server screen (operation panel) might lock if the screen is
switched from “Copier” to “Document Server” while the Document Server is
saving a print job.
Note: The Document Server function itself (from WIM) and all other operation
panel screens work correctly.
It is possible to set Sp6-006-1 or 4 to a value of –3.0(mm) to –5.0(mm), even
though the setting range is –2.5(mm) to +5.0mm.
Note:
-
As a result, lines appear on the copy surface when the value is set to –
3.0 to –5.0.
-
In addition to this main unit controller version, be sure to update the
BICU firmware to v1.10:03 or later.
Communication between RC Gate and the device does not work correctly.
The Key Counter counts up when a FAX is printed out.
Conditions:
-
Sp5121-001 is ON (default setting: OFF)
-
“FAX” is selected in Key Counter Management
1.09
Changed:
1.The following SPs have been newly added.
- SP5-886-001 (ROM Update)
Allows to access the ROM by the Remote Firmware Update function
[0 ~ 1/ 0 / 1/step] (0: Yes, 1: No)
- SP5-005-001 (IP Address Display)
Display the IP Address on the LCD.
[0 ~ 1/ 0 / 1/step] (0: No, 1:Yes)
Note:
These above functions are only available if all 3 of NCS firmware ver 4.17 or
later, Controller firmware Ver 1.08 or later and Websys firmware Ver 1.02 or
later have been applied to the device.
Fixed: Users cannot log into an MFP via Windows Authentication using a
domain controller in a different subnet unless WINS is enabled
(GFPR#RC05060014).
Fixed :If the devices receives more than 300 login attempts without cycling
the power, the error message SC991 will be displayed on the operation panel
and users will not be able to login to the device. This can happen no matter
where the logins attempts are made from the operation-panel, WIM, in print
data.
Fixed: The error code for Remote firmware update is remained even if the
Remote Firmware Update is successful.
Fixed: The username and password will still be contained in the fields when
someone opens the login screen by pressing the User Tools button. This
occurs if username and password are left in the field without logging in.
After a large number of documents (more than 80K) are printed in color, the
device will stall.
Fixed: The page numbering might not be printed correctly if a stored
document in the Document Server is printed with the Magzine function and
page numbering.
Fixed: The thumbnails of the stored files are blurry when they are displayed
in Web Image Monitor, DeskTopBinder or DeskTopEditor for Production. This
occurs only when data is scanned from a device with File Format Converter.
V1.08