Other (Firmware History)
This is to inform you of the Main Unit Controller firmware history.
Part No.
Program name
B1545550
B1545550L.fwu
V1.13
June production ‘06
B1545550K.fwu
V1.12
May production ‘06
B1545550J.fwu
V1.11
February production ‘06
B1545550H.fwu
V1.10
December production ‘05
B1545550G.fwu
V1.09
November production ‘05
B1545550F.fwu
V1.08
October production ‘05
B1545550E.fwu
V1.07
August production ‘05
B1545550D.fwu
V1.06
June production ‘05
B1545550C.fwu
V1.05
May production ‘05
B1545550B.fwu
V1.04
April production ‘05
B1545550A.fwu
V1.03
March production ‘05
-
B1545550.fwu
V1.02
-
February production ‘05
Symptom Corrected
Version
Incorrect wording (“Dammy test”) is sometimes displayed when the key
counter is not inserted.
The machine sometimes hangs if the authentication process is cancelled
repeatedly.
The machine sometimes hangs if a large number of originals are scanned for
copying.
1.13
The machine may stall when the operator changes the Authentication
settings in Administrator Tools and then exits System Settings.
It takes a long time to download the Address data with SmartDeviceMonitor
for Admini.
SC687 may occur after the “Tray Full” (Finisher) message is cleared in
Magazine Mode.
1.12
A display error may occur if the key counter is not in the key counter holder
when the main power is turned on.
The Data Overwrite function only uses the NSA method, even when another
method is selected.
1.11
Sometimes, the counter data is not transferred to the RC Gate Center.
1.10