Fusing and Exit
SM
4-39
M156/M157/M176/M177
R
ep
lac
em
en
t
a
n
d
A
d
ju
s
tm
e
n
t
When reinstalling the fusing lamp
The flat terminal [A] must be placed on the right side of the fusing unit (fusing cable side).
4.9.5 HOT ROLLER
1. Fusing lamp (page 4-38 "Fusing Lamp")
2. Brackets [A] ( x 2 each)
3. Turn over the fusing unit.
4. Fusing upper cover [A] ( x 4)
5. Fusing front cover [A] ( x 2)