Fusing and Exit
M156/M157/M176/M177
4-36
SM
After installing a new fusing unit
1. Enter the "Maintenance Mode".
2. Select "Engine Maintenance", and then press the "OK" key.
3. Select "Reset Fuser Unit" and then press "OK" key.
4. Press the left key “Execute” of the “Selection keys”.
5. Exit the "Maintenance Mode".
4.9.2 THERMOSTAT
Do not recycle a thermoswitch that is already opened. Safety is not guaranteed if you do
this.
1. Fusing unit (page 4-34 "Fusing Unit")
2. Fusing upper cover [A] ( x 4)
3. Thermostat [A] ( x 2)