Service Call
SM
6-7
M156/M157/M176/M177
T
ro
u
b
le
s
h
o
o
ti
n
g
Defective fusing relay
Defective fusing relay circuit
S24V fuse on the PSU
Unstable power supply.
1. Check the power supply source.
2. Replace the +24V fuse on the PSU.
3. Replace the PSU
559
Fuser 3times jam error
The paper jam counter for the fusing unit reaches 3. The paper jam counter is
cleared if the paper is fed correctly.
This SC is activated only when this function is enabled with "Engine
Maintenance" (default "OFF").
Defective fusing unit
Defective fusing control
1. Clear this SC to send a command after a jam removal.
2. Turn off this function after a jam removal.
Execute "Fuser SC Reset" to recover the machine after completing the
recovery procedure. Otherwise, the machine continues to issue this SC
code and cannot be operated.
SC 6xx (Communication and Other Error)
669
EEPROM communication error
An unexpected value exists in the initialization flag of the EEPROM
EEPROM not connected
Defective EEPROM
1. Installing the EEPROM.
2. Replacing the EEPROM.
Summary of Contents for M156
Page 1: ...M156 M157 M176 M177 SERVICE MANUAL ...
Page 14: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Page 19: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None ...
Page 22: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 29: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None ...
Page 87: ...SERVICE TABLES REVISION HISTORY Page Date Added Updated New None ...
Page 116: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None ...
Page 136: ...ENERGY SAVE REVISION HISTORY Page Date Added Updated New None ...
Page 143: ...M156 M157 M176 M177 SERVICE MANUAL APPENDICES ...
Page 145: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None ...
Page 154: ...ERROR MESSAGES REVISION HISTORY Page Date Added Updated New None ...