When the main switch is turned on, the CPU turns on the fusing lamp. When
the fusing thermistor detects the ready temperature, the machine enters the
ready condition. After the ready temperature is detected, the CPU keeps the
fusing temperature at 190
°
C for one minute, then the target temperature is
changed to 120
°
C (120 V machines) or 130
°
C (230 V machines).
When the
key is pressed, if the fusing lamp temperature is higher than
the ready temperature, the machine starts copying immediately. If the
temperature is lower, the fusing lamp is turned on and the start indicator turns
red and blinks. Copying starts after the fusing temperature reaches the ready
temperature, and the fusing temperature is kept at 190ÉC during copying.
After copying is finished, the fusing temperature is kept at 190
°
C for one
minute.
To prevent any copy quality problem caused by exposure lamp intensity
fluctuation, the fusing lamp does not turn on while the exposure lamp is on,
even if the fusing temperature drops below 190
°
C.
Det
ailed
Descript
ions
20 December 1996
IMAGE FUSING
2-53
Summary of Contents for FT 4015
Page 2: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 14: ...SECTION 2 DETAILED DESCRIPTIONS...
Page 71: ...SECTION 3 INSTALLATION...
Page 90: ...SECTION 4 SERVICE TABLES...
Page 118: ...SECTION 5 PREVENTIVE MAINTENANCE...
Page 126: ...SECTION 6 REPLACEMENT AND ADJUSTMENT...
Page 190: ...SECTION 7 TROUBLESHOOTING...
Page 222: ...SECTION 8 OPTIONS...
Page 223: ...SECTION 9 APPENDIX TIMING CHART...
Page 225: ...COPIER A219 ELECTRICAL COMPONENT LAYOUT 4 2 3 1 5 6 A219S500 wmf...
Page 226: ...10 15 14 13 12 11 9 8 7 18 17 16 A219S501 wmf...
Page 227: ...24 40 23 28 27 26 25 19 20 21 22 29 39 31 32 33 34 35 36 38 37 30 A219S502 wmf...