8.1.2 Image Density Adjustment
When:
The customer requires the image density to be either darker or lighter.
Purpose:
To get proper image density.
Method:
SP34
How it works:
Changes the ac drive/dc power board output voltage.
NOTE: SP34 settings can be changed by customers.
- SP34: Image Density Adjustment (ADS Mode) -
Setting
0
1
2
3
4
Bias Voltage
Change [V]
±
0
–40
+40
–40
+40
Exposure Lamp Change
±
0
±
0
±
0
+4 steps
–4 steps
Image Density
Normal
Lighter
Darker
Lightest
Darkest
1 step = 0.5 V (120 V machines) or 1.0 V (230 V machines)
- SP62 V
L
Correction Interval -
Setting
V
L
Correction Interval
0
2 steps/8,000 copies
1
2 steps/6,000 copies
2
2 steps/4,000 copies
3
2 steps/2,000 copies
4
2 steps/1,000 copies
5
No correction
1 step = 0.5 V (120 V machines) or 1.0 V (230 V machines)
Replacement
Adju
stment
20 December 1996
COPY QUALITY ADJUSTMENT
6-51
Summary of Contents for FT 4015
Page 2: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 14: ...SECTION 2 DETAILED DESCRIPTIONS...
Page 71: ...SECTION 3 INSTALLATION...
Page 90: ...SECTION 4 SERVICE TABLES...
Page 118: ...SECTION 5 PREVENTIVE MAINTENANCE...
Page 126: ...SECTION 6 REPLACEMENT AND ADJUSTMENT...
Page 190: ...SECTION 7 TROUBLESHOOTING...
Page 222: ...SECTION 8 OPTIONS...
Page 223: ...SECTION 9 APPENDIX TIMING CHART...
Page 225: ...COPIER A219 ELECTRICAL COMPONENT LAYOUT 4 2 3 1 5 6 A219S500 wmf...
Page 226: ...10 15 14 13 12 11 9 8 7 18 17 16 A219S501 wmf...
Page 227: ...24 40 23 28 27 26 25 19 20 21 22 29 39 31 32 33 34 35 36 38 37 30 A219S502 wmf...