8.6 TRANSFER CURRENT ADJUSTMENT
ADJUSTMENT STANDARD
Adjusting VR
SP Mode
DC –350
±
4
µ
A
VRT
SP9-3
NOTE: Normally, each High Voltage Supply Board spare part is adjusted in
the factory before shipment. This adjustment is not required when
the board is replaced.
+
WARNING
Very high voltage is applied from the high voltage supply unit
terminals. Pay extreme attention when adjusting the drum current.
Make sure that the machine is unplugged before connecting the
multimeter.
1. Remove the rear cover. (See Rear Cover Removal.)
2. Disconnect the connector from the T corona current terminal [A]. Then
connect the ground terminal of the multimeter to the connector [B], and
connect the positive terminal to the T terminal of the high voltage supply
board as shown in the illustration.
NOTE: Make sure that the connector [B] is not in contact with the T
terminal [A].
4. Turn on the transfer corona using SP9-3.
5. Adjust the drum current by turning VRT on the high voltage supply board.
[A]
[B]
A219R563.wmf
COPY QUALITY ADJUSTMENT
20 December 1996
6-56
Summary of Contents for FT 4015
Page 2: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 14: ...SECTION 2 DETAILED DESCRIPTIONS...
Page 71: ...SECTION 3 INSTALLATION...
Page 90: ...SECTION 4 SERVICE TABLES...
Page 118: ...SECTION 5 PREVENTIVE MAINTENANCE...
Page 126: ...SECTION 6 REPLACEMENT AND ADJUSTMENT...
Page 190: ...SECTION 7 TROUBLESHOOTING...
Page 222: ...SECTION 8 OPTIONS...
Page 223: ...SECTION 9 APPENDIX TIMING CHART...
Page 225: ...COPIER A219 ELECTRICAL COMPONENT LAYOUT 4 2 3 1 5 6 A219S500 wmf...
Page 226: ...10 15 14 13 12 11 9 8 7 18 17 16 A219S501 wmf...
Page 227: ...24 40 23 28 27 26 25 19 20 21 22 29 39 31 32 33 34 35 36 38 37 30 A219S502 wmf...