11.3 FUSING LAMP CONTROL
The CPU monitors the temperature of the hot roller surface using a
thermistor. The fusing lamp is turned on and off to keep the hot roller surface
at the target temperature. The target temperature depends on the machine
condition as follows:
Machine Condition
Fusing Lamp ON/OFF
Threshold
Remarks
Ready
165
°
C: 120 V machines
172
°
C: 230 V machines
—
After the main switch is turned
on, until one minute has passed
since the fusing temperature
reached the Ready condition.
190
°
C
After the fusing temperature
reaches the ready temperature,
the fusing lamp is kept on until
it reaches 190
°
C.
After the above time period, the
copier enters the energy saver
mode.
120
°
C: 120 V machines
130
°
C: 230 V machines
When the
key is pressed,
the red indicator blinks and
copying starts after the fusing
temperature reaches the Ready
condition.
During copying
190
°
C
—
A219D533.wmf
IMAGE FUSING
20 December 1996
2-52
Summary of Contents for FT 4015
Page 2: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 14: ...SECTION 2 DETAILED DESCRIPTIONS...
Page 71: ...SECTION 3 INSTALLATION...
Page 90: ...SECTION 4 SERVICE TABLES...
Page 118: ...SECTION 5 PREVENTIVE MAINTENANCE...
Page 126: ...SECTION 6 REPLACEMENT AND ADJUSTMENT...
Page 190: ...SECTION 7 TROUBLESHOOTING...
Page 222: ...SECTION 8 OPTIONS...
Page 223: ...SECTION 9 APPENDIX TIMING CHART...
Page 225: ...COPIER A219 ELECTRICAL COMPONENT LAYOUT 4 2 3 1 5 6 A219S500 wmf...
Page 226: ...10 15 14 13 12 11 9 8 7 18 17 16 A219S501 wmf...
Page 227: ...24 40 23 28 27 26 25 19 20 21 22 29 39 31 32 33 34 35 36 38 37 30 A219S502 wmf...