3.2 CHARGE CORONA WIRE AND CHARGE CORONA GRID
REPLACEMENT
1. Open the front cover.
2. Remove the imaging unit. (See Imaging Unit Removal.)
3. Remove the charge corona unit [A] (1 screw) from the imaging unit.
4. Remove the grid [B] from the charge corona unit, as shown by [C].
5. Remove the front endblock cover [D] and the rear endblock cover [E].
6. Unhook the spring [F] from the corona wire and replace the wire.
NOTE: 1) The new corona wire must be in the groove of the front
endblock [F] as shown.
2) Do not handle the new corona wire with bare hands. Oil on the
wire may cause uneven charge on the drum.
3) Do not rub the corona wire with rough material (sandpaper,
etc.). This will damage the corona wire.
4) Do not use any solvents to clean the wire. This will cause
uneven charge on the drum.
5) Do not damage the grid plate when replacing the corona wire.
6) Oils and chemicals from your hands will deteriorate the grid
plate.
7) Do not bend the grid plate. This can result in an uneven
charging.
[E]
[B]
[F]
[C]
[D]
[F]
A219R518.wmf
[A]
A219R560.wmf
Replacement
Adju
stment
20 December 1996
AROUND THE DRUM
6-19
Summary of Contents for FT 4015
Page 2: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 14: ...SECTION 2 DETAILED DESCRIPTIONS...
Page 71: ...SECTION 3 INSTALLATION...
Page 90: ...SECTION 4 SERVICE TABLES...
Page 118: ...SECTION 5 PREVENTIVE MAINTENANCE...
Page 126: ...SECTION 6 REPLACEMENT AND ADJUSTMENT...
Page 190: ...SECTION 7 TROUBLESHOOTING...
Page 222: ...SECTION 8 OPTIONS...
Page 223: ...SECTION 9 APPENDIX TIMING CHART...
Page 225: ...COPIER A219 ELECTRICAL COMPONENT LAYOUT 4 2 3 1 5 6 A219S500 wmf...
Page 226: ...10 15 14 13 12 11 9 8 7 18 17 16 A219S501 wmf...
Page 227: ...24 40 23 28 27 26 25 19 20 21 22 29 39 31 32 33 34 35 36 38 37 30 A219S502 wmf...