3-6
3. Secure the PCFE board [E] to the bracket
[F]
(3 screws).
4. Attach the RS232C port [G] to the shield
plate
(2 screws, 2 hexagon nuts).
Place the shield cover [H] to the shield
plate.
5. Attach the PCFE bracket [F] to the
machine (2 screws).
6. Connect the PCFE harness [I] to the
FCU [J] (CN2) and the PCFE board
(CN2).
Route the harness as shown.
NOTE: Bend the PCFE harness prior to
connecting to the FCU as shown.
7. Connect the RS232C harness [K] to the
PCFE board (CN1).
Bend the cable under the connector as shown.
8. Replace the FCU shield plate, G4 cover and the top cover.
9. Attach the core [L] to the RS232C cable.
Connect the PC-Fax Expander port with the PC port
using the RS232C cable.
Plug in the machine and turn on the main switch.
Set System bit switch 06 bit 5 to “1.” Then turn the main
switch off and on to enable the PC-Fax Expander.
Print the system parameter list and make sure that “PC-Fax Expander” is listed
as an option on the list.