21 May, 1999
BIT SWITCHES
4-41
Service
Tables
G3 Switch 0A
FUNCTION
COMMENTS
4
Maximum allowable frame
interval during image data
reception.
0: 5 s 1: 13 s
This bit determines the maximum interval
between each EOL signal (end-of-line) or
between each ECM frame from the other end.
Try using a longer setting if error code 0-21 is
frequent.
5
Not used
Do not change this setting.
6
Reconstruction time for the
first line in receive mode
0: 6 s 1: 12 s
When a computer controls the sending terminal,
there may be a delay in receiving page data
after the local machine accepts set-up data and
sends CFR. If this occurs, set this bit to 1 to give
the sending machine more time to send data.
Refer to error code 0-20.
7
Not used
Do not change this setting.
G3 Switch 0B
FUNCTION
COMMENTS
0
Protocol requirements: Europe
0: Disabled 1: Enabled
1
Protocol requirements: Spain
0: Disabled 1: Enabled
2
Protocol requirements:
Germany
0: Disabled 1: Enabled
3
Protocol requirements: France
0: Disabled 1: Enabled
4
PTT requirements: Germany
0: Disabled 1: Enabled
Program these bit switches manually to match
local requirements.
5-7
Not used
Do not change these settings.
G3 Switch 0C
FUNCTION
COMMENTS
0
1
Pulse dialing method
Bit 1 Bit 0 Setting
0 0 Normal (P=N)
0 1 Oslo (P=10 - N)
1 0 Sweden (N+1)
1 1 Not used
P = Number of pulses sent out, N = Number
dialed.
2-7
Not used
Do not change these settings.
G3 Switch 0D - Not used (do not change these settings)
G3 Switch 0E - Not used (do not change these settings)
G3 Switch 0F - Not used (do not change these settings)