4.5.9 Digital I/O Menu
This section provides a flow chart and descriptions for the Digital I/O menu.
Figure 4-25. Digital I/O Menu
4.5.10 Analog Output Menu
This section provides a flow chart and descriptions for the Analog Output menu. The Analog Output menu is only functional if
the analog output option card is installed. If the option card is not installed, the menu is visible, but not functional. If the analog
output option card is installed, configure all other indicator functions and calibrate the indicator before configuring the analog
output. Instructions to install and setup the analog output option card are provided with the option card kit (PN 195084).
Figure 4-26. Analog Output Menu
Table 4-22. Digital I/O Menu Parameters
Parameter
Description
Bit 1-4
Digital I/O Bit 1-4 – Specifies the mode and function of the digital I/O pins;
Settings:
Off
(default), Print, Zero, Tare, Units,
Primary, Secondary, Clear, Display Accumulator, Display Tare, Clear Accumulator, Clear Tare, Net/Gross, Gross, Net,
Clear Consecutive Number, Keyboard Lock, Batch Run, Batch Start, Batch Pause, Batch Reset, Batch Stop, Output
Table 4-23. Analog Output Menu Parameters
Parameter
Description
Source
Specifies the scale tracked by the analog output; Only appears if the Regulatory Mode parameter is set to Industrial;
Settings:
Scale 1
(default), Remote
Mode
Specifies the weight data, gross or net, tracked by the analog output when the Source parameter is assigned to a scale;
Settings:
Gross
(default), Net
Output
Specifies the type/range of the output;
Settings:
0-10V
(default), 0-20MA, 4-20MA
Error Action
Specifies how the analog output responds to system error conditions;
Settings:
Full Scale
(default)
– Set to full scale (10 V or 20 mA)
Hold
– Holds current value
Zero Scale
– Sets to zero value (0 V, 0 mA or 4 mA)
Minimum
Weight
Specifies the minimum weight value tracked by the analog output;
Enter value: ±9999999.0,
0.0
(default)
Maximum
Weight
Specifies the maximum weight value tracked by the analog output;
Enter value: ±9999999.0,
10000.0
(default)
Tweak Zero
Adjusts the offset of the analog output zero value;
Enter value: 0–65535,
0
(default)
Tweak Span
Adjusts the offset of the analog output span value;
Enter value: 0–65535,
59515
(default)
Slot 0
Slot 0
Slot 0
Setup
Tare
User
Digital I/O
Setpoint
Analog Output
Source
Mode
Tweak Span
Setup
Tare
User
Analog Output
Digital I/O
Softkey
Output
Minimum Weight
Maximum Weight
Tweak Span
Tweak Zero
Error Action