100
Visit our website
Percent Relative
Performs functions based on a specified percentage of the target value of a referenced setpoint,
using the same weight mode as the referenced setpoint; the actual target value of the Percent
Relative setpoint is calculated as a percentage of the target value of the referenced setpoint
X
X
Pause
Pauses the batch sequence indefinitely; a Batch Start signal must be initiated to continue the
batch process
X
Delay
Delays the batch sequence for a specified time; the length of the delay (in tenths of a second) is
specified on the Value parameter
X
Wait Standstill
Suspends the batch sequence until the scale is at standstill
X
Counter
Specifies the number of consecutive batch sequences to perform; place counter setpoints at the
beginning of a batch routine
X
Auto-Jog
Automatically checks the previous weight-based setpoint to verify the setpoint weight value is
satisfied in a standstill condition
• If the previous setpoint is not satisfied when at standstill, the
Auto-Jog
setpoint activates
the digital output of the previous weight-based setpoint for a period of time, specified on
the Value parameter (in tenths of a second)
• The Auto-Jog process repeats until the previous weight-based setpoint is satisfied when
the scale is at standstill
NOTE: The Auto-Jog digital output is typically used to signify an Auto-Jog operation is
being performed.
NOTE: Auto-Jog uses the digital output of the previous weight-based setpoint, and
should not be assigned to the same digital output as the related weight-based setpoint.
X
Center of Zero
Monitors for a gross center of zero condition
• The digital output associated with this setpoint kind is activated when the referenced scale
is at center of zero
• No value is required for this setpoint
X
In Motion
Monitors for an in-motion condition
• The digital output associated with this setpoint is activated when scale is not at standstill
• No value is required for this setpoint
X
In Range
Monitors for an in-range condition
• The digital output associated with this setpoint is activated when the scale is within
capacity range
• No value is required for this setpoint
X
Batch in Process
Batch processing signal:
• The digital output associated with this setpoint is activated whenever a batch sequence is
in progress
• No value is required for this setpoint
X
Timer
Tracks the progress of a batch sequence based on a timer
• The timer value, in tenths of a second, determines the length of time allowed between start
and end setpoints
• Start and End parameters are used to specify the start and end setpoints
• If the End setpoint is not reached before the timer expires, the digital output associated
with this setpoint is activated
X
Concurrent
Allows a digital output to remain active over a specified portion of the batch sequence
•
Type 1 (Value = 0):
The digital output associated with this setpoint becomes active when
the Start setpoint becomes the current batch step and remains active until the End setpoint
becomes the current batch step
•
Type 2 (Value > 0):
If a non-zero value is specified for the Value parameter, the value
represents the timer, in tenths of a second, for this setpoint; The digital output associated
with this setpoint becomes active when the Start setpoint becomes the current batch step
and remains active until the timer expires
X
Time of Day
Performs functions when the internal clock time of the indicator matches the specified
setpoint time
X
X
Always
This setpoint is always satisfied; It is typically used to provide an endpoint for true/false
branching batch routines
X
Never
This setpoint is never satisfied; Used to branch to a designated setpoint in true/false branching
batch routines in which the batch does not continue through the normal sequence of batch
setpoints
X
Table 14-1. Setpoint Kinds (Continued)