16.0 Appendix
16.1 Error Messages
The 682 indicator provides a number of error messages. When an error occurs, the message displays on the indicator.
16.1.1 Displayed Error Messages
The 682 provides a number of front panel error messages to assist in problem diagnosis.
lists these messages and
their meanings.
Table 16-1. 682 Error Messages
Error Message
Description
-------
Overflow error – Weight value too large to be displayed
Gross > overload limit – Gross value exceeds overload limit; Check configuration or signal input level; Overload can
be caused by input signal > 45 mV or common mode voltage > 950 mV
v v v v v v v
Gross < underload limit – Gross value exceeds underload limit
Battery low
Displays every 30-seconds when battery is low
Waiting for 30 seconds of standstill Displays when power up delay is active
Not allowed in motion
Displays when attempting to perform a function while weight is in motion, if in motion is not allowed for that function
Tare in motion not allowed
Displays when attempting to perform a tare while weight is in motion, if in-motion tares are not allowed
Tare not allowed
Displays when attempting to perform a tare, if a tare is not allowed
Negative tare not allowed
Displays when attempting to perform a negative tare, if a negative tare is not allowed
Keyed tare not allowed
Displays when attempting to perform a keyed tare, if a keyed tare is not allowed
Tare exceeding capacity not allowed Displays when attempting to perform a tare larger than capacity, if it is not allowed
Multiple tares not allowed
Displays when attempting to perform a tare if a tare is already in the system, if tare is not configured to
replace or remove
Must be in first interval to tare
Interval is currently within the second or third interval; Perform tare while in the first interval only
Keyed tare value must be in first
interval
Keyed tare value is within the second or third interval; Keyed tare value must be within the first interval only
Duplicate ID not allowed
Displays when attempting to enter a Truck ID that already exists, if ID Overwrite is set to Disable
Invalid ID
Displays when attempting to enter an invalid Truck ID; Truck IDs can be up to 16 alphanumeric characters in length
Truck ID not found
Displays when attempting to enter a Truck ID at Weigh Out that has not been previously entered
Truck program disabled
Displays when attempting a Truck Mode function, when Truck Mode is set to Off
Truck program error
Generic error for the truck program
Invalid Index
Displays when attempting to delete a truck ID record with an invalid index
Invalid Weight
Displays when weigh-in/-out procedure weight is invalid
Record read error
Displays when an error occurs while reading from the microSD card or the CRC wasn't valid on the record
Record write error
Displays when an error occurs while writing to the microSD card
Initial zero failed
Displays when an attempt to perform an initial zero fails, only possible at startup
Please wait
Displays when calibrating
Alarm
Displays when a configured setpoint’s ALARM action occurs
vvv
vvv
v