Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
37
RS-485
Configurable parameters for RS-485/422 serial communications port; Sub-Parameters:
Trigger – Sets the input trigger type;
Settings:
Command
(default)
– Allows operation of EDP commands and printing
Stream Industrial
– Scale data is updated up to configured sample rate; Allows operation of EDP commands and
printing
Stream Legal for Trade
– Scale data is updated at configured display update rate; Allows operation of EDP commands
and printing
Remote
– Configures the port to operate as a serial scale input
Fieldbus
– Configures the port to operate for Fieldbus; Automatically configures all port parameters for Fieldbus and
hides the port parameters in the menu
NOTE: When in STRIND, STRLFT and REMOTE, if the Communications port is set to RS-485, the port does not
stream data.
Baud – Sets the transmission speed for the port;
Settings: 1200, 2400, 4800,
9600
(default), 19200, 28800, 38400,
57600, 115200
Bits – Sets number of data bits transmitted or received by the port and specifies the parity bit to odd, even or none;
Settings:
8NONE
(default), 8EVEN, 8ODD, 7EVEN, 7ODD
Stop Bits – Sets the number of stop bits transmitted or received by the port;
Settings:
1
(default), 2
Line Terminator – Sets the termination character for data sent from the port;
Settings:
CR/LF
(default), CR
End of Line Delay – Sets the delay period from when a formatted line is terminated to the beginning of the next formatted
serial output (0.1-second intervals);
Enter value: 0–255,
0
(default)
Echo – Specifies if characters received by the port are echoed back to the sending unit;
Settings:
On
(default), Off
Response – Specifies if the port transmits replies to serial commands;
Settings:
On
(default), Off
Address – Specifies address used to connect to the port; Must be set to 0 for RS-422;
Enter value: 0–255,
0
(default)
Duplex – Specifies FULL (4-wire) or HALF (2-wire) duplex used to connect to the port;
Settings:
FULL
(default), HALF
Serial Option Card
Port 1-2
Configurable parameters for the serial option card ports; Sub-Parameters:
Port Type – Sets the serial port type;
Settings:
RS-232
(default), RS-485
Trigger – Sets the input trigger type;
Settings:
Command
(default)
– Allows operation of EDP commands and printing
Stream Industrial
– Scale data is updated up to configured sample rate; Allows operation of EDP commands and
printing
Stream Legal for Trade
– Scale data is updated at configured display update rate; Allows operation of EDP commands
and printing
Remote
– Configures the port to operate as a serial scale input
Fieldbus
– Configures the port to operate for Fieldbus; Automatically configures all port parameters for Fieldbus and
hides the port parameters in the menu
Baud – Sets the transmission speed for the port;
Settings: 1200, 2400, 4800,
9600
(default), 19200, 28800, 38400,
57600, 115200
Bits – Sets number of data bits transmitted or received by the port and specifies the parity bit to odd, even or none;
Settings:
8NONE
(default), 8EVEN, 8ODD, 7EVEN, 7ODD
Stop Bits – Sets the number of stop bits transmitted or received by the port;
Settings:
1
(default), 2
Line Terminator – Sets the termination character for data sent from the port;
Settings:
CR/LF
(default), CR
End of Line Delay – Sets the delay period from when a formatted line is terminated to the beginning of the next formatted
serial output (0.1-second intervals);
Enter value: 0–255,
0
(default)
Echo – Specifies if characters received by the port are echoed back to the sending unit;
Settings:
On
(default), Off
Response – Specifies if the port transmits replies to serial commands;
Settings:
On
(default), Off
Address – Specifies address used to connect to the port (RS-485 only); Must be set to 0 for RS-422;
Enter value: 0–255,
0
(default)
Duplex – Specifies FULL (4-wire) or HALF (2-wire) duplex used to connect to the port (RS-485 only);
Settings:
FULL
(default), HALF