![Rice Lake REVOLUTION 682 Synergy Plus Technical Manual Download Page 47](http://html1.mh-extra.com/html/rice-lake/revolution-682-synergy-plus/revolution-682-synergy-plus_technical-manual_1453947047.webp)
Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
39
4.5.4.3 Ethernet Menu
This section provides a flow chart and descriptions for the Ethernet menu.
Figure 4-13. Ethernet Menu
Table 4-12. Ethernet Menu Parameters
Parameter
Description
Ethernet MAC ID Displays the Ethernet MAC address (read only):
00:00:00:00:00:00
DHCP
Dynamic Host Configuration Protocol (static allocation of IP address when OFF);
Settings:
On
(default), Off
Enabled
Enables Ethernet communications;
Settings:
Off
(default), On
IP Address
IP Address;
Enter value:
0.0.0.0
(default)
Subnet
Subnet Mask;
Enter value:
255.255.255.0
(default)
Gateway
Default Gateway;
Enter value:
0.0.0.0
(default)
Ethernet Server
Allows the 682 to receive external EDP commands;
Sub-parameters:
Trigger – Sets the input trigger type;
Settings:
Command
(default), Stream Industrial, Stream Legal For Trade, Remote
Port – Specifies IP Address port to open to establish communications;
Enter value: 1025–65535,
10001
(default)
Name – Host name for Ethernet Server;
Enter characters: Alphanumeric entry up to 30 characters,
0
(default)
Line Terminator – Sets the termination character for data sent from the port;
Settings:
CR/LF
(default), CR
Echo – Specifies if characters received by the port are echoed back to the sending unit;
Settings:
Off
(default), On
Response – Specifies if the port transmits replies to serial commands;
Settings:
On
(default), Off
Ethernet Client
Allows the 682 to send EDP commands to external devices;
Sub-parameters:
Trigger – Sets the input trigger type;
Settings:
Command
(default), Stream Industrial, Stream Legal For Trade, Remote
Remote IP Address – Sets the remote IP Address;
Enter value:
0.0.0.0
(default)
Remote Port – Specifies IP Address port to look for to establish communications;
Enter value: 1025–65535,
10001
(default)
Line Terminator – Sets the termination character for data sent from the port;
Settings:
CR/LF
(default), CR
Echo – Specifies if characters received by the port are echoed back to the sending unit;
Settings:
On
(default), Off
Response – Specifies if the port transmits replies to serial commands;
Settings:
On
(default), Off
End of Line Delay – Sets the delay period from when a formatted line is terminated to the beginning of the next formatted
serial output (0.1-second intervals);
Enter value: 0–255,
0
(default)
Disconnect Time – Sets the disconnect timeout (in seconds);
Enter value: 0–60,
0
(default)
Http Server
Enables the remote HTTP web server (
);
Settings:
Off
(default), On