![REX RKF 130 General Information Manual Download Page 55](http://html.mh-extra.com/html/rex/rkf-130/rkf-130_general-information-manual_1449159055.webp)
RKF 130
Operating the piston filler
Version 1.1
Page 55 of 128
4.5
DESCRIPTION OF THE BUTTONS
4.5.1
Speed
This value in pieces per minute (pc/min) determines the speed during the
portioning procedure.
If the speed is selected in % in the correction mask, the speed can be set
from 1-100%.
4.5.2
Weight (capacity)
The maximum 6-digit number (setting range from 5 to 99999.9 cm³)
determines the capacity and thus the weight of the portion. Ensure that
the initial quantity is added during the first portioning procedure after a
filling break and a possible return is also added to the capacity of this first
portioning. In addition, the weight correction value in the respective
correction mask must be taken into account.
4.5.3
Filling break
Time that should pass between the filled portions (setting range from 0-
3000 ms) if the portioning chain has not been interrupted by pressing the
knee lever (pay attention to the 1-2-3 knee lever position). This value is
insignificant if every portioning is started by pressing the knee lever.
4.5.4
Clip impulse
This value (setting range from 50-3000 ms) determines the time of the
clip signal.
4.5.5
Additional capacity of the 1
st
portion
This value having the unit cm³ is always deducted from or added to the
capacity when the portioning/twisting-off procedure has been interrupted
for the duration of approximately 10 seconds (setting range from –100
cm³ to 100 cm³).