5.2.4
Cleaning for alkaline cleaning procedure
Workflow
Cleaner
Cleaning
method
Devices/
agent
Instructions
Coarse
cleaning,
removing the
product
residues
Water,
max. 50-60°C
manual,
mechanical
Water hose,
scraper,
trowel
Begin immediately
after end of
production
Dismantling
and cleaning
small parts
2-5 % solution of
e.g.:
Henkel: P3-topax
19
Henkel: P3-topax
66
Goldschmidt:
SOMPLEX fat
solvent
First through pre-
rinsing with water
max. 60°C, then
allow foaming or
manual,
application time
~ 15min
High
pressure
cleaner, low
pressure
foaming
device or
brushes or in
tub
Rinsing
Water having
drinking water
quality ~60°C
Low pressure
< 30 bar manual
Low
pressure
cleaning
device,
water hose
Inspecting
cleanliness
visual
Clean when required
Disinfecting
0.5-2 % solution of
e.g.:
Henkel: P3-topax
99
Henkel: P3-topax
91
Goldschmidt:
TEGO 2000
TEGO IMC
Spraying,
foaming;
application time
as per product
data sheet
High
pressure
cleaner,
low pressure
device,
spray pistol
All piston fillers and
small parts (after
completing all the
cleaning measures to
be executed in the
room)
Rinsing
Drinking water
Low pressure
< 30 bar, manual
Low
pressure
device,
spray pistol,
water hose
Execute rinsing
according to LMBG
§31
Drying
Maintaining
e.g. white oil
spraying/rubbing
in
Spray pistol
Roasting cylinder,
external surface of
the machine