File or Folder
Description
instruments are the Keysight 34401A Ref.
, the
The PLT has been tested with all three instruments.
binaries/
Contains the necessary firmware binaries used during
DUT testing.
binaries/GU/prod_test_GU.bin
Contains the GU latest firmware binary. Users should
better upgrade their PLT hardware with the GU
firmware contained in this folder.
binaries/GU/flash_programmer_GU.bin
This firmware is used to upgrade the GU firmware by
the
GU_fw_upgrade.exe
application.
ble_tester_instr_plugins/
Contains the Bluetooth
®
LE tester instrument DLLs.
ble_tester_instr_plugins/mt8852b.dll
This is the DLL that performs the Direct Test Mode RF
tests using the Anritsu MT8852B instrument Ref.
Note:
There is an issue in Anritsu MT8852B firmware
version 4.20.000 and should be upgraded to the latest
one. Latest MT8852B instrument firmware can be
downloaded from the following link:
https://www.anritsu.com/en-US/test-
measurement/support/downloads?model=MT8852B
ble_tester_instr_plugins/IQxelM.dll
This is the DLL that performs the Direct Test Mode RF
tests using the Litepoint IQxel-M instrument Ref.
icons/
Contains pictures used by the PLT applications.
IQmeasure_3.1.2/
Contains specific Litepoint IQxel-M DLLs as released by
Litepoint.
params/
Contains the configuration
params.xml
file, the XML
schema
params.xsd
and a sample of BD address file
named
bd_address.ini
.
params/custom_mem_data.csv
This is a sample CSV file to be used in the custom
memory burn action. Users could edit this file and add
their own specific memory data to be burned by the
PLT. The PLT will match the entries in the CSV file
using the BD addresses. The format of the file is
explained later.
scripts/
Contains sample batch script files. User can select
batch script files to be executed by the PLT before and
after each test.
scripts/run_before_tests.cmd
An example script that copies and renames binaries
from a directory to a folder required by the PLT. This
folder is accessed by the PLT to read and burn different
binaries per DUT.
scripts/run_after_tests.cmd
An example script that moves all logs files, except the
ones with the current date, to a specific folder.
temp_meas_instr_plugins/
Contains the temperature measurement instrument
DLLs.
temp_meas_instr_plugins/ni_usb_tc01.dll
The
ni_usb_tc01.dll
is the DLL used to interface a NI
temperature sensor for temperature
measurements.
temp_meas_instr_plugins/tmu_temp_sens.dll
The
tmu_temp_sens.dll
is the DLL used to interface a
measurements.