UM-B-041
SmartBond Production Line Tool
User Manual
Revision 4.8
02-Nov-2022
CFR0012
149 of 170
© 2022 Renesas Electronics
Appendix P CSV Log File Contents
describes the CSV File columns (Section
) generated during PLT testing. In general, not all CSV file columns shown in
will be
printed, but only those that relate to the enabled tests and memory operations user has selected. An example is given in Appendix
Table 77: CSV File Contents
Header
Value
Description
Start time
hh:mm:ss
Shows the time the test procedure has started
End time
hh:mm:ss
Shows the time the test procedure has ended
Tester ID
ID
The tester ID name.
DUT
1-16
The PLT connector for the DUT. Values 1-16.
BD address
XX:XX:XX:XX:XX:XX
The BD address assigned for this device.
Overall status
PASS\FAIL
The overall final test result for this DUT.
COM Port
XX
Windows assigned COM Port
Temperature test
PASS\FAIL
Shows the temperature measured during temperature test. The first column shows
the result of the test. The second column shows the temperature measured.
Temperature
xx.xx
Programmer FW download 1
PASS\FAIL
uartboot_da1470x.bin
FW download. The first column shows the result of the
programmer firmware download procedure. The second column shows the path to
the firmware.
Programmer FW path 1
C:\folder\to\bin
Programmer FW version get 1
PASS\FAIL
The firmware version of the programmer firmware (
uartboot_da1470x.bin).
The
first column shows the result of the firmware version acquisition. The second
column shows the actual firmware version.
Programmer FW version 1
x.x.x.x
GPIO Watchdog mem 1
[‘Test Name’]
PASS\FAIL
The GPIO watchdog operation for the programmer firmware
(
uartboot_da1470x.bin).
RAM FW download
PASS\FAIL
Production test FW download through memory programming FW. The first column
shows the result of the production test firmware download procedure. The second
column shows the path to the firmware.
RAM FW path
C:\path\to\bin