Table 26: Test Options
Option
Description
Production tests
This option enables the production test operations.
Memory programming
This option enables the memory programming operations.
Notify user for OTP burning
When this option is enabled, PLT informs the user with all the OTP burning
tests that are enabled. A pop-up message appears, prompting the user
whether to proceed with the tests.
Firmware download retries
Configures the firmware download retries in case of an error during firmware
download.
Re-test failed DUTs
When this option is enabled, any DUT that failed will immediately be retested
with the exact same options, including the
BD address
. This option is the
same to the
Retest failed DUTs - Enable
Enable VBAT and UART at
the end of the tests
Enables the VBAT lines and UART communication between the PC and the
devices after all the tests have finished. If enabled, DUTs will remain powered
after the end of the tests.
Reset VBAT
If this option is enabled the VBAT line will be toggled. If not selected, the
DUTs will not be rebooted, thus their system RAM will have the last test
firmware downloaded by the PLT (either the
st_fw_da1470x.bin
or the
uartboot_da1470x.bin
).
Run script before testing
starts
This option enables the execution of a batch or an executable before the
device testing procedure starts. As described in Section
the success
return code should be a value between 0 and 100 for the tool not to report an
error. Any other value will be taken as error and prevent the tool from running
the tests.
Enable script timeout
Enables a wait timeout for the script to finish. The time to wait is set in the
timeout
field below. If this option is disabled PLT will wait until the script ends.
Timeout
The time to wait for the script to finish.
Script path
The path of file to execute when the
Run script before testing starts
option is
enabled.
Run script when testing is
finished
This option enables the execution of a batch or an executable after the device
testing procedure has finished. The success return code should be 0 for the
tool not to report an error.
Enable script timeout
Enables a wait timeout for the script to finish. The time to wait is set in the
timeout
field below. If this option is disabled, PLT will wait until the script
ends.
Timeout
The time to wait for the script to finish.
Script path
The path of file to execute when the
Run script when testing is finished
option
is enabled.