UM-B-041
SmartBond Production Line Tool
User Manual
Revision 4.8
02-Nov-2022
CFR0012
63 of 170
© 2022 Renesas Electronics
describes the available options for the
RF RX
test
using the
Golden Unit
as a transmitter.
In the RF RX test, the Golden Unit sends 500 packets. The DUTs are set in receive mode and the
RSSI is measured. If the RSSI measured by the DUT reception is less than the specified
RSSI limit
,
the device will fail, and the tests will stop for that particular device.
Table 34: Golden Unit RF Tests
Option
Description
Enable
This option enables the specific RF RX test using the Golden Unit as a transmitter.
Test name
The name assigned to each test. The assigned name will be shown on the tab and
next to it an indication showing whether the specific test is enabled or not.
Frequency
The Bluetooth
®
LE channel frequency used in the RF RX test using the Golden Unit.
RSSI limit
The RSSI limit for pass/fail criteria in the RF RX test using the Golden Unit. If the
average RSSI of the device after it has received the packets transmitted from the
Golden Unit is less than this value, the test will be considered as failed.
Packet error limit
This configures the PER limit for pass/fail criteria. If the percentage of the correct
packets received is less than the value entered here, the test will fail.
BLE Tester
In the
BLE Tester
panels, several tests can be enabled that require an external Bluetooth
®
LE tester
instrument. More detailed information about the Bluetooth
®
LE tester can be found in Ref.
BLE Tester - General
Figure 50: BLE Tester General Settings
General
settings for the
BLE
Tester
supported tests. Any available external
instrument found by the
ble_tester_driver
DLL and their interfaces can be selected.
Table 35: BLE Tester General Settings
Option
Description
Enable
This option enables the
BLE Tester
tests, which include:
●
Bluetooth
®
LE Tester TX Power
●
Frequency Offset