7.2.6.9
Custom Test
Figure 60: Custom Test
Custom tests
can have multiple instances with different settings. Tests can be added and removed
using the two buttons (e.g.,
and
in
) at the bottom right side of each panel.
Note:
When adding or removing a test all settings are refreshed with the values written to the XML
file, meaning that any unsaved settings will be lost.
describes the available options for the
Custom Tests
.
When enabled, the PLT software will send an HCI command through UART to activate a customer-
defined test that will run on the DUTs. The HCI custom test command will contain a single byte as
data (the
Command ID
byte), to be used mainly as identification for a specific test in the firmware.
Default functionality of the production test firmware is to respond with the same
Command ID
.
Otherwise, the test will be considered as failed.
Table 44: Custom Tests Options
Option
Description
Enable
This option enables the specific custom test.
Test name
The name assigned to each test. The assigned name will be shown on the tab and
next to it an indication showing whether the specific test is enabled or not.
Command ID
The byte that will be sent to the device running the production test firmware.
7.2.6.10
External 32 kHz Test
Figure 61: External 32 kHz Test
describes the available options for the External 32 kHz
Tests
.
Table 45: External 32 kHz Tests Options
Option
Description
Enable
This option enables the external 32 kHz low power clock test.