UM-B-041
SmartBond Production Line Tool
User Manual
Revision 4.8
02-Nov-2022
CFR0012
76 of 170
© 2022 Renesas Electronics
Option
Description
Wait time
The time in ms the PLT will wait before taking a current measurement, after it has
sent an instruction to the DUTs to go into a specific sleep state. Supported values are
1 to 500000 ms.
Sleep time (only for
extended sleep)
The time in seconds that the DUTs will remain in extended sleep mode. A timer in the
production test firmware will wake up the devices and set them to idle mode.
Supported values are 1 to 9 sec for DA14580/1/2/3 and up to 1200 sec for the rest.
Range
The range value in Ampere units that the ammeter will operate. Supported values are
0 to 9999 and default value is 0.001 A. When the
ammeter_scpi.dll
is used, if this
value is set to zero, the instrument will use the automatic range functionality.
Resolution
The ammeter resolution value in Ampere units.
Samples
The number of samples that the ammeter will read and average. 1 to 1000 is
supported.
SCPI cmd
A SCPI command to be passed to the ammeter just before the measurement is
taken. Supports multiple commands separated with a column. Up to 256 characters
are supported.
Upper limit
The upper limit value for the sleep current measurement test procedure, for a single
DUT.
Next to this input field the total upper limit current consumption for all the enabled
DUTs is shown, which is the value to be used during testing.
Note:
During testing, some DUTs may fail until the current measurement test takes
place; in that case, the PLT will automatically re-calculate the total upper limit by
using the value given for a single DUT multiplied with the number of the active DUTs
at the time that the test will run.
Low limit
The low limit value for the sleep current measurement test procedure, for a single
DUT.
Next to this input field the total upper limit current consumption for all the enabled
DUTs is shown, which is the value to be used during testing.
Note:
During testing, some DUTs may fail until the current measurement test takes
place; in that case, the PLT will automatically re-calculate the total low limit by using
the value given for a single DUT multiplied with the number of the active DUTs at the
time that the test will run.
7.2.6.12
Temperature Measurement Test
Figure 63: Temperature Measurement Test
describes the available options for the
Temperature Measurement Test
.
Table 49: Temperature Measurement Test
Option
Description
Enable
This option enables the Temperature measurement test.