26. 8-Bit Timer (TMR)
26.4.4
Timing of Counter Clear by Compare Match
TCNT is cleared when compare match A or B occurs, depending on the settings of the TCR.CCLR[1:0] bits.
shows the timing of this operation.
Figure 26.9
Timing of Counter Clear by Compare Match
26.4.5
Timing of the External Reset for TCNT
TCNT is cleared at the rising edge or high level of an external counter reset signal, depending on the settings of the
TCR.CCLR[1:0] bits. At least 2 PCLK cycles are required from a reset input to clearing of TCNT.
and
show the timing of this operation.
Figure 26.10
Clear Timing by External Counter Reset Signal (Rising Edge)
Figure 26.11
Clear Timing by External Counter Reset Signal (High Level)
Compare match signal
TCNT
PCLK
N
00h
TMRIn pin
Clear signal
TCNT
PCLK
2 PCLK
N – 2
N – 1
N
00h
01h
TMRIn pin
Clear signal
PCLK
2 PCLK
TCNT
N – 2
N – 1
N
00h