R01UH0823EJ0100 Rev.1.00
Page 1771 of 1823
Jul 31, 2019
RX23W Group
51. Electrical Characteristics
Figure 51.23
HOCO Clock Oscillation Start Timing (After Reset is Canceled by Setting OFS1.HOCOEN Bit to 0)
Figure 51.24
HOCO Clock Oscillation Start Timing (Oscillation is Started by Setting HOCOCR.HCSTP Bit)
Figure 51.25
PLL Clock Oscillation Start Timing (PLL is Operated after Main Clock Oscillation Has Been
Stabled)
Figure 51.26
Sub-Clock Oscillation Start Timing
RES#
Internal reset
HOCO clock
OFS1.HOCOEN
t
RESWT
HOCO clock
HOCOCR.HCSTP
t
HOCO
PLLCR2.PLLEN
PLL clock
MOSCCR.MOSTP
t
MAINOSC
Main clock oscillator output
t
PLL
Sub-clock oscillator output
SOSCCR.SOSTP
t
SUBOSC