R01UH0823EJ0100 Rev.1.00
Page 1220 of 1823
Jul 31, 2019
RX23W Group
36. CAN Module (RSCAN)
36.2.28
Receive Buffer Register nBL (RMTSn) (n = 0 to 15)
This register can be read when the GRWCR.RPAGE bit is 1.
RMTS[15:0] Bits (Receive Buffer Timestamp Data)
These bits indicate the timestamp value of the message stored in the receive buffer.
Address(es): RSCAN.RMTS0 000A 83A4h, RSCAN.RMTS1 000A 83B4h, RSCAN.RMTS2 000A 83C4h,
RSCAN.RMTS3 000A 83D4h, RSCAN.RMTS4 000A 83E4h, RSCAN.RMTS5 000A 83F4h,
RSCAN.RMTS6 000A 8404h, RSCAN.RMTS7 000A 8414h, RSCAN.RMTS8 000A 8424h,
RSCAN.RMTS9 000A 8434h, RSCAN.RMTS10 000A 8444h, RSCAN.RMTS11 000A 8454h,
RSCAN.RMTS12 000A 8464h, RSCAN.RMTS13 000A 8474h, RSCAN.RMTS14 000A 8484h,
RSCAN.RMTS15 000A 8494h
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
RMTS[15:0]
Value after reset:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
Symbol
Bit Name
Description
R/W
b15 to b0
Receive Buffer Timestamp Data
Timestamp value of the received message can be read.
R