R01UH0136EJ0210 Rev.2.10
Page 437 of 800
Jul 31, 2012
M16C/64A Group
22. Remote Control Signal Receiver
Table 22.16
Registers and Setting Values in Input Capture Mode (Independent Operation) (1/2)
Register
Bit
Function
PMC0
PMC1
PMCiCON0
EN
Set to 1.
Set to 1.
SINV
Select input signal polarity.
Select input signal polarity.
FIL
Select filter enabled or disabled.
Select filter enabled or disabled.
EHOLD
Set to 0.
-
HDEN
Set to 0.
Set to 0.
SDEN
Set to 0.
-
DRINT0
Set to 00b.
-
DRINT1
PMCiCON1
TYP0
Select measuring object.
Select measuring object.
TYP1
CSS
Set to 0.
-
EXSDEN
Set to 0.
-
EXHDEN
Set to 0.
-
PMCiCON2
ENFLG
Flag indicating PMC0
operated/stopped.
Flag indicating PMC1
operated/stopped.
INFLG
Input signal flag.
Input signal flag.
CEFLG
Counter overflow flag.
Counter overflow flag.
CEINT
Set to 1 when using counter
overflow interrupt.
Set to 1 when using counter
overflow interrupt.
PSEL0
Set to 01b.
Set to 10b.
PSEL1
PMCiCON3
CRE
Set to 1.
Set to 1.
CFR
Set to 1.
Set to 1.
CST
Set to 1.
Set to 1.
PD
Set to 1.
Set to 1.
CSRC0
Select clock source.
Select clock source.
CSRC1
CDIV0
Select count source divisor.
Select count source divisor.
CDIV1
PMCiSTS
CPFLG
Not used (read as undefined value)
-
REFLG
Not used (read as undefined value) Not used (read as undefined value)
DRFLG
Not used (read as undefined value) Not used (read as undefined value)
BFULFLG
Not used (read as undefined value)
-
PTHDFLG
Not used (read as undefined value) Not used (read as undefined value)
PTD0FLG
Not used (read as undefined value) Not used (read as undefined value)
PTD1FLG
Not used (read as undefined value) Not used (read as undefined value)
SDFLG
Not used (read as undefined value)
-
i = 0, 1
-: Unimplemented bits in PMC1
Note:
1.
This table does not describe a procedure.
Summary of Contents for M16C/60 Series
Page 853: ...M16C 64A Group R01UH0136EJ0210...