12. Serial RapidIO Registers > RapidIO Error Management Extension Registers
307
Tsi576 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
24:31
ERR_
RATE_
CNT
Error Rate Counter
These bits maintain a count of the number of transmission errors that have
been detected by the port. This number is decremented by the Error Rate Bias
function. The counter cannot over or underflow and continue to increment or
decrement as defined, even if thresholds are met. Software can reset this
counter. If the value of the counter equals the error rate threshold trigger
register, an error is reported.
For more information see the
RapidIO Interconnect Specification
(Revision 1.3), Part 8: Error Management Extensions Specification
.
R/W
0
(Continued)
Bits
Name
Description
Type
Reset
Value