12. Serial RapidIO Registers > RapidIO Error Management Extension Registers
300
Tsi576 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
11
CS_NOT_ACC_
EN
Enable error rate counting.
Received packet-not-accepted control symbol.
R/W
0
12
PKT_ILL_ACKID_
EN
Enable error rate counting.
Received packet with unexpected ackID.
R/W
0
13
PKT_CRC_ERR_E
N
Enable error rate counting.
Received packet with a CRC error.
R/W
0
14
PKT_ILL_SIZE_
EN
Enable error rate counting.
Received packet exceeds 276 bytes.
R/W
0
15:25
Reserved
N/A
R
0
26
LR_ACKID_ILL_
EN
Enable error rate counting.
A received Link Response control symbol contains an ackID that is
not outstanding.
R/W
0
27
PROT_ERR_EN
Enable error rate counting.
Protocol Error. Received Control Symbol is unexpected.
R/W
0
28
Reserved
N/A
R
0
29
DELIN_ERR_EN
Enable error rate counting
Delineation Error
Received unaligned /SC/or/PD/ or undefined code-group.
R/W
0
30
CS_ACK_ILL_EN
Enable error rate counting
An unexpected acknowledge control symbol was received.
R/W
0
31
LINK_TO_EN
Enable error rate counting
An acknowledge or Link-response is not received within the
specified time-out interval.
R/W
0
(Continued)
Bits
Name
Description
Type
Reset
Value