24
Remeha Avanta 18v
LTALW7H000035b
X10
59970LTGBW7H043d
E
Terminal
Block X4
- Live
- Neutral
System pump
2
1
4
3
X4
2.7.11 Connecting a PC/PDA
Using the optional Recom interface package a PC or PDA can
be connected to the X10 “telephone connector”. Using the
Recom PDA service software you can load, change and down-
load various boiler settings and readings. See the user instruc-
tions supplied with the software/hardware.
Not all PDA will run the Recom software - check with Broag
before buying a unit.
2.8 Connecting an external pump
Connect the system pump to terminal X4 (X4 -1 and X4 -2)
of the control unit. The pump’s earth connection must be con-
nected to the control unit’s earth connection with an AMP-con-
nector (supplied with boiler). The cable must be fed through
the boiler’s casing by means of the supplied cable gland
and
run trough the cable clamp on the right-hand inside of the
boiler.
LTALW7H000035
59970LTGBW7H043