36
Remeha Avanta 18v
LTALW7H000047b
R
The parameters can be changed from the stand-by status as
follows:
•
Press the
[enter]
-key
and briefly the
[reset]-
key
until codes
c
and
0
appear alternately in the display.
•
Press the
[+]
-key
until access code
12
is displayed.
•
Press the
[enter]
-key until
p1
appears (codes
p
[
and
[
1
are displayed alternately);
•
This parameter can now be changed as follows;
•
Press the
[enter]
-key; the set value for the maximum flow
temperature now appears e.g.;
75
(75°C).
•
Press the
[+]
or
[-]-
key to change this value, for example to
65
(65°C).
•
Press
[enter]
-key to confirm the value; codes
p
[
and
[
1
are displayed alternately.
•
Press the
[+]
-key
to change
the next parameter, etc.
•
Press
[reset]
-key to return to the operating mode.
The boiler will automatically return to the normal operating
mode if no keys are pressed for 10 minutes.
LT.AL.W7H.000.047