![RCbenchmark 1780 Series User Manual Download Page 35](http://html1.mh-extra.com/html/rcbenchmark/1780-series/1780-series_user-manual_792739035.webp)
Series 1780 Dynamometer User Manual V1.1
Document ID: Q2D4F5
Publish date: 2020-03-06
Please retrieve the mechanical safety stop bag (#LXCM) from the carton box:
Item name
Item SKU
Qty
Mechanical stop metal strip
YFXL
1
M5 x 55 mm socket head screw
GPQL
2
15 mm long spacer
UGFD
2
M5 flange lock nut
YTEX
2
❏
From the previous operation 4.2.3, you shall only have installed six screws to connect
the load measurement unit and the profile plate.
❏
Pass the M5 x 55 mm socket head screws through the outer holes on the metal strip.
❏
Align the 15 mm spacers on the other side of the strip, install it onto the lower plate.
❏
Turn in the M5 flange nut on the side of the rectangle profile. The whole assembly is
shown in Fig 4.24.
❏
Now you can fasten all six screws and nuts.
Fig 4.24: Installation of the mechanical safety stop
Copyright 2019 - Tyto Robotics Inc.
Page 35/65