55M4300CCE00 Rev A
Adjust the boom angle to the target angle, when the boom is at the correct angle for
calibration the display will change to show:
3)
Press
“
”
, the display will change to show one of these screens:
Carefully lift the test load until it is just clear of the ground. Accurately measure the
actual radius of the suspended load from the centre line of slew of the machine.
4)
Use
“
”
or
“
”
to adjust the Corr.:
x.x
value until the displayed
radius equals the measured radius, note that the indicated radius should
normally be increased, not decreased. Press
“
”
to accept the change, the
system will confirm the calibration is saved.
5)
Press
“
”
to return to the main calibration menu.
Carefully set the test load on the ground.
Summary of Contents for i4300