55M4300CCE00 Rev A
1)
Use
“
”
or
“
”
to highlight “Load offset” and press
“
”
to enter.
Where
Load:
represents the suspended load reading and
0.00
represents the offset
factor (a value of 0.00 signifies that there is no applied offset). The main boom should
be at an angle of approximately 60°. When positioning the machine remember to make
the last derrick motion boom up. Carefully lift the test load until it is just clear of the
ground.
2)
Use
“
”
or
“
”
to modify the load offset factor until the
displayed load is equal to the test load and press
“
”
to accept the change, the
system the system will confirm the calibration is saved.
3)
Press
“
”
to return to the main calibration menu.
Carefully set the test load on the ground.
Summary of Contents for i4300